Structural design to the full Australian Standards suite — AS/NZS 1170 (actions), AS3600 (concrete), AS4100 (steel), AS2870 (residential slabs and footings) — with wind and seismic loads per AS/NZS 1170.2/.4.
Australian projects follow a specific suite of Standards that differ from Eurocode in load factors, materials, and detailing. I design directly to AS3600 (concrete), AS4100 (steel), AS2870 (residential slabs), and AS/NZS 1170 (loading) — not by converting a Eurocode design.
That means correct load combinations from AS/NZS 1170.0, wind loads from AS/NZS 1170.2 with the right terrain category and importance level, and rebar/steel detailing to Australian practice.
Dead + live per AS/NZS 1170.1, wind per 1170.2, earthquake per 1170.4.
ULS / SLS combinations per AS/NZS 1170.0 with correct load factors.
AS3600 for concrete, AS4100 for steel, AS2870 for residential slabs.
Bearing pressure from geotech + AS2159 for piles, AS2870 for residential.
Calc package with Standards clause references throughout.
SpaceGass is the Australian industry standard for steel structures; RAPT handles most concrete design cleanly.
Yes — Class A to Class H2 (and Class E on request). Requires the site classification report.
This depends on the specific council and jurisdiction. I can produce calcs and drawings; local sign-off may be needed via a partner engineer where required.
Yes — Section B of the NCC references AS Standards; I flag any deemed-to-satisfy vs performance-based issues.